<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-08 21-20-41
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 59 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 59 kHz 13561 11,5331
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,8 dBr 4,68 dBr 6,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 59 kHz MIN: 9 kHz % above 76 kHz: 11,5331 Acquired: 2025/05/08 21.19.37 Total samples: 13561 Equivalent time: 0:11:18 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400 500
FM Scope MAX: 6,3 dBr MIN: 0,8 dBr AVE: 4,68 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2025/05/08 21.19.36) 21.06 21.08 21.10 21.12 21.14 21.16 21.18 0 2 4 6 Pm [dBr]